- When interfacing the PI-963 with the HU-961 with a serial number higher than
380, there is a jumper inside the HU-961 that needs to be changed. You will need to
remove the top of the HU-961 and as you are facing the unit, this small
black computer jumper strap is in the right rear corner on the right hand side of the I/O
Connector and in front of a small blue capacitor. The jumper will be
on the two left pins or two inner pins. It needs to be moved to the two right pins
or two outside pins.
[Home] [Broadcast
Products] [Cable Products] [Fixes]
[Support] [Updates]
[Sales] [Info] [Search]